1-999/1$color:
Depend on productCondition:
NEWDetail
The IC694MDL660 is a component module of the PACSystem RX3i Programmable Automation Controller (PAC) family. This module was originally manufactured by GE Intelligent Platform and is now manufactured by Emerson Automation. This module features high density, thirty-two (32) point input channels, particularly group separation, and has 4 (4) input groups, each consisting of eight (8) channels. The IC694MDL660 is designed for an input current of 7.0 mA per point at nominal voltage and an input signal voltage of 0 to 30 VDC at a nominal input of 24 VDC. Each channel of this module has an on-state voltage range of 11.5 to 30 VDC and an off-state voltage of 0 to 5 VDC. The maximum on-state current is 3.2 mA and the maximum off-state current is 1.1 mA. You can also choose a configurable filter time to fine-tune each input channel. Selectable input filters such as 0.5ms, 1.0ms, 2.0ms, 5ms, 10ms, 50ms, 100ms allow the module to eliminate false negatives and false negatives often caused by environmental and mechanical factors such as dust and debouncing can be ignored. The filter settings you select will result in response times when turning the input point on and off. This module specifically requires the use of high density terminal blocks such as the box style, part number IC694TBB032, or the front spring terminal block, part number IC694TBS032. Each input channel has its own input LED indicator that shows the logic state of the device. When the LED is lit, it indicates a logic 1, meaning the input channel is actively receiving input power, otherwise the LED is disabled.
The IC694MDL660 input module is a logic input module manufactured by GE Fanuc Automation and included in the RX3i PACSystem series. Designed for use with RX3i racks. This module has 32 inputs that can operate with positive or negative logic. These inputs are divided into groups, each capable of operating with voltages up to 30 volts. Each of the four input groups has a common connection. The isolation voltage between these groups is up to 250 volts AC continuous and up to 1500 volts AC for 1 minute. The IC694MDL660 logic input module from GE Fanuc Automation has a DC voltage of 24 volts and each input operates with an input voltage range of 0 to 30 volts DC. The IC694MDL660 logic input module from GE Fanuc Automation has a selectable input filter time of 0.5 ms to 100 ms. The on and off times are set after the user sets the filter time. This module consumes 300 mA of current including all inputs. GE Fanuc Automation's IC694MDL660 logic input module includes a diagnostic tool consisting of a terminal block that reports directly to the RX3i CPU. This module has a current of 7.0 mA per input at nominal voltage. One of the requirements for successful use of this module is that it must be connected to an RX3i CPU with release 2.90 or higher. Do not use with 30-90 series CPUs as they are incompatible. The resolution of this module is 48 input bits and 16 output bits.
Specification
IC694MDL660 is a 24 VDC positive/negative logic input module
Provides 32 separate input points. The input is positive or negative
It is a logic input and operates at levels up to 30V.
The inputs are arranged in 8 separate groups, with each group having its own common interface. There is isolation between the four groups of inputs, but each group of eight inputs points to the same common user connection.
The MDL660 module provides 7 selectable input filter times. The filter time can be set by the programmer based on the output data reference assigned to the module.
32 green LEDs indicate the on/off status from 1 to 32 points.
The red/green TB LED is removable from the module
It is green when the terminal block is attached. Terminal Block
It is red when you do not lock it. The module also adds a terminal block to the RX3i CPU
Sends a terminal block loss message to report the terminal block status.
The blue band on the label indicates that MDL660 has a low voltage.
Indicates that it is a module.
This module can be installed in any I/O slot of the RX3i system. Must be used with the RX3i CPU (version 2.90 or later). Not available with 90-30 series PLC CPUs.
The MDL660 module uses 48 input bits and 16 output bits
Exchange point status and filter information
IS200BICLH1AFF | IS200TBAIH1CCC |
IS200BICLH1BAA | IS200TBAIH1CED |
IS200BICLH1BBA | IS200TBCIH1B |
IS200BPVCG1BR1 | IS200TBCIH1BBC |
IS200DSPXH1DBD | IS200TBTCH1CBB |
IS200EACFG3BAA | IS200TDBTH2ACC |
IS200EBKPG1C | IS200TDBTH6ABC |
IS200EDCFG1BAA | IS200TDBTH6ACD |
IS200EDEXG1B | IS200TPROH1BBB |
IS200EHPAG1D | IS200TPROH1CAA |
IS200EPBPG1A | IS200TREGH1BDB |
IS200EPCTG1AAA | IS200TRLYH1BED |
IS200EPSMG2AEC | IS200TRLYH1BFD |
IS200ERBPG1ACA | IS200TRLYH1BGF |
IS200ERDDH1ABA | IS200TRLYH1BGG |
IS200ERIOH1AAA | IS200TRPAH2AHE |
Ms Josslyn Yin
Email: sales21@htechplc.com / josslynyin@qq.com
Whatsapp/Wechat: +86 18059274803 / +86 18759670213
Address: Room 1904, No.96-2 Lujiang Road, Siming District, Xiamen
To get lowest price with best original quality,pls don`t hesitate to leave a message here.Thank you!