YOKOGAWA SCP451-11 PROCESSOR MOUDLE CPU
YOKOGAWA SCP451-11 PROCESSOR MOUDLE CPU 100% Brand New. 365 days warranty.
item no.:
AAM10lead time:
2-3 work daysproduct orgin:
Japanshipping port:
Xiamen Chinapayment:
T/Tmarket price:
$999price range:
1-999/1$color:
Depends on the materialAAM10/AAM11/AAM11B In Stock
A2SAM105 (For Upgrade AAM10/AAM11/AAM11B)
Voltage Input range: 0 to 10 V DC
Current Input range: 0 to 20 mA DC (*2)
Data update period: For A2SAM105 alone : 2 ms (*7)
Extended function: Current input, voltage input, and isolated channels
Withstanding voltage: Between field and the system: 1500 V AC for 1 minute, 42 V DC
Mounting: Mounted on the nest for I/O adaptor (A2BA3D)
Wiring connection: Connected to the terminals of the A2BA3D (with M4 screws or ELCO connector)
Input signal setting: Input signals and input signal ranges are set by the software
Weight: 0.1kg
*1: An auxiliary voltage output equipped with AAM11 and AAM11B is not available for A2SAM105.
*2: The combination with MTL barrier 728 is valid, however, the minimum operating voltage of a 2-wire transmitter must be 12 V DC or lower where the wiring resistance is 10 Ω.
*3: The module input resistance viewed from the terminals is calculated as below: 240 Ω + (voltage drop in the input protection circuit / current value).
*4: When the power of A2SAM105 is off or overcurrent is detected, the current input loop is open.
*5: Operation when A2SAM105 detects over current depending on style is different. Style S1 : When over current is detected and the protection circuit operates, the system alarm (Adaptor Fail) is notified to HIS. Style S2 or later : When over current is detected and the protection circuit operates, the system alarm (Adaptor Fail) is not notified to the HIS. The abnormal state is detected as IOP (input open).
*6: If the input current is 25 to 40 mA due to the inrush current of the equipment or the like, connect a zener diode and bypass the current. For details, refer to "CENTUM VP Installation Guidance" (TI 33J01J10-01EN).
*7: The data update period is max. 10 ms, when the A2SAM105 is used with the A2MME041 I/O module.
*8: The internal power supply is empowered by I/O modules housed in the A2BA3D.
*9: The BRAIN communication function supported by AMM11B is not available for A2SAM105.
*10: Up to 5 HART communication field devices (e.g. transmitter) can be connected to A2SAM105 by multi drop connection. A2SAM105 can drive up to 24 mA including inrush current of field devices.
To get lowest price with best original quality,pls don`t hesitate to leave a message here.Thank you!