YOKOGAWA SCP451-11 PROCESSOR MOUDLE CPU
YOKOGAWA SCP451-11 PROCESSOR MOUDLE CPU 100% Brand New. 365 days warranty.
item no.:
UT130-RN/HBAlead time:
2-3daysproduct orgin:
JAPANpayment:
T/TCondition:
newUT130 Model and Suffix Codes
UT130
48x48x100mm
3-digit display
Number of SP: 2
UT130-RN Without alarm/Without other options/Relay output
UT130-VN Without alarm/Without other options/Voltage pulse output
UT130-RN/AL With 2 alarms/Without other options/Relay output
UT130-VN/AL With 2 alarms/Without other options/Voltage pulse output
UT130-RN/AL/RS With 2 alarms/With communication/Relay output
UT130-VN/AL/RS With 2 alarms/With communication/Voltage pulse output
UT130 Temperature controller (48 x 48 x 100mm)
Control output-R-Relay output (time-proportional PID or on/off control)
Control output-V-Voltage pulse output (time-proportional PID control)
Fixed -N-Fixed
Options/AL-Alarm outputs (2 points) (Note1)
Options/HBA-Heater disconnection alarm (includes the function of " /AL" option) (Note 1)
Options/RS-Communication function (Note 2)
Options/V24-Power Supply 24V DC / 24V AC
UT130 Temperature controller (48 x 48 x 100mm)
Control output for heating-R-Relay output (time-proportional PID or on/off control)
Control output for heating-V-Voltage pulse output (time-proportional PID control)
Control output for cooling-R-Relay output (time-proportional PID or on/off control)
Control output for cooling-V-Voltage pulse output (time-proportional PID control)
Option/AL-Alarm outputs (2 points) (Note1)
Option/HBA-Heater disconnection alarm (includes the function of " /AL" option) ((Notes 1 and 2)
Option/RS-Communication function (Notes 2 and 3)
Option/V24-Power Supply 24V DC / 24V AC
L4000FB:Terminal cover for models UT130 and UT150 (1 set)
L4000FA:Mounting bracket for models UT130 and UT150 (1 piece)
UT130-RN/HBA Names and Functions of Each Part
Lit when SP is displayed or being changed.
Flashes slowly (approx. once every second) when a parameter code is displayed.
Flashes fast when a parameter value is being changed.
AL1: Lit when the alarm 1 is activated.
AL2: Lit when the alarm 2 is activated.
In the operating display, it switches between the PV (measured value) and SP (target setpoint) displays.
Registers the data value changed using the data change keys.
Switches between operating displays or parameter setting display sequentially.
Pressing the key for 3 seconds or more in the operating display retrieves the operating parameter setting display. You can transfer to the setup parameter setting display form the operating parameter setting display.
Pressing the key for 3 seconds or more in either an operating or setup parameter setting display transfers back to the operating display.
In the operating display, either PV (measured value) or SP (target setpoint) is indicated.
Which parameter takes precedence over the other depends on the parameter "DSP" value.
In the parameter setting display, either the parameter codes or parameter value is indicated.
If an error occurs, the error code is displayed.
Lit while control output is being output.The left lamp lights up in orange during control output of standard type.
Flashes according to the control output value during timeproportional output. (Flashes slowly when control output value is small; flashes fast when control output value is large.)
UT130-RN/HBA BASIC OPERATIONS
This chapter describes an operating procedure using temperature controllers UT130 and UT150 of standard type with the alarm option as an example. Regarding the operating procedure for the heating/cooling type controller or for the controller with the options other than the alarm,the alarm,confirm whether the some parameters appear or not referring to the parameter flowchart in “3. NAMES AND FUNCTIONS OF EACH PART /PARAMETERS.” The operating procedure for UT152/UT155 is the same as that for UT150.
UT130-RN/HBA DATASHEET DOWNLOAD
To get lowest price with best original quality,pls don`t hesitate to leave a message here.Thank you!