WOODWARD 9907-167 505E Digital Governer Steam Turbines
Digital Governer Steam Turbines
item no.:
5441-413lead time:
1-3 daysproduct orgin:
USAshipping port:
Xiamenpayment:
T/TCondition:
New
Product ID:V-13567
Condition:In Stock
Brand:WOODWARD
Model:5441-413
An interface module is used to control electrical loads by providing a means to turn them on or off. It usually consists of multiple relays arranged in a module along with the circuitry and connectors required to interface with other systems. It acts as an interface between a control system such as a microcontroller or programmable logic controller (PLC) and the loads that need to be controlled. Each channel of the module corresponds to a separate relay, allowing multiple electrical devices to be controlled independently.
Features
*The module typically has input terminals that connect to the control system and output terminals that connect to the electrical loads. Control signals from the control system activate the relays, which then turn the corresponding loads on or off. Depending on the module, each relay may be able to handle different voltages and currents, thereby controlling various types of loads.
*The modules use the VERSA Modular Eurocard (VME) bus standard for connector specifications and data transfer. Core-to-core and slot-to-slot logic and power connections are made through an etched circuit motherboard. I/O connections are made through cables from the front of the board to field terminal modules in the cabinet.
Characteristics
*Allows multiple relays or switches to be controlled by digital signals from a control system such as a programmable logic controller (PLC) or microcontroller. It provides the necessary circuitry to drive the relays and open or close the relays based on the control signals received.
*Provides a variety of input and output channels. The input channels receive digital control signals from the control system, while the output channels drive the relays or switches. The number of channels may vary depending on the specific CRIM model.
*To ensure proper electrical isolation between the control system and external devices, CRIMs typically contain isolation circuitry. This isolation protects the control system from electrical noise, voltage spikes, and other interference that may be present in the external environment.
*Supports a variety of communication protocols to interface with the control system. Common protocols include Modbus, Profibus, Ethernet/IP, CANbus, etc. The choice of protocol depends on the requirements of the specific application and compatibility with the control system.
Contact Informations
Ms Josslyn Yin